Commercial EMC Test Systems
To apply CE or UKCA markings, a Commercial EMC assessment should be performed to demonstrate compliance with the European EMC Directive or the UK EMC Regulations.
This page provides details of test systems available for testing commercial products, according to the Harmonised test methods. Most product-specific standards refer back to these tests, but please contact us if your required test method is not listed.
The links above each table take you to the System Product Page, where further information on the equipment provided with the system can be found. When ordering the system, please quote the option number.
Item 951 - Conducted Emissions System
| Option No. | Test Method | Applications |
|---|---|---|
| #1 | CISPR 16-2-1 | Low Voltage AC Mains |
| #2 | CISPR 16-2-1 | DC Power |
| #3 | CISPR 32 | Telecom / Network |
Item 952 - Radiated Emissions System
| Option No. | Test Method | Application |
|---|---|---|
| #1 | CISPR 16-2-3 | Enclosure Port |
Item 953 - Harmonics / Flicker System
| Option No. | Test Method | Applications |
|---|---|---|
| #1 | EN 61000-3-2 | Low Voltage AC Mains |
| #2 | EN 61000-3-3 | Low Voltage AC Mains |
Item 954 - Conducted Immunity System (All in One)
| Option No. | Test Method | Application |
|---|---|---|
| #1 | EN 61000-4-6 | Signal Ports |
| #2 | EN 61000-4-6 | DC Power Ports |
| #3 | EN 61000-4-6 | AC Power Ports |
Item 955 - Conducted Immunity System (Bespoke)
| Option No. | Test Method | Application |
|---|---|---|
| #1 | EN 61000-4-6 | Signal Ports |
| #2 | EN 61000-4-6 | DC Power Ports |
| #3 | EN 61000-4-6 | AC Power Ports |
Item 957 - Radiated Immunity System (G-TEM)
| Option No. | Test Method | Application |
|---|---|---|
| #1 | EN 61000-4-3 | Enclosure Ports |
Item 958 - Magnetic Field Immunity System
| Option No. | Test Method | Application |
|---|---|---|
| #1 | EN 61000-4-8 | Enclosure Ports |
Item 959 - Electrostatic Discharge (ESD) System
| Option No. | Test Method | Application |
|---|---|---|
| #1 | EN 61000-4-2 | Enclosure Ports |
Item 961 - Transient Immunity System
| Option No. | Test Method | Application |
|---|---|---|
| #1 | EN 61000-4-4 | Signal Ports |
| #2 | EN 61000-4-4 | DC Power Ports |
| #3 | EN 61000-4-4 | AC Power Ports |
| #4 | EN 61000-4-5 | Signal Ports |
| #5 | EN 61000-4-5 | DC Power Ports |
| #6 | EN 61000-4-5 | AC Power Ports |
| #7 | EN 61000-4-11 | AC Power Ports |
| #8 | EN 61000-4-34 | AC Power Ports |
Need Help Selecting the Right Commercial Test System?
Contact EMC Hire's engineering team to discuss your CE or UKCA commercial EMC testing requirement.
Most product-specific standards refer back to these harmonised test methods. If your required test method is not listed, please contact us and we will advise on the most suitable system.