Skip to content
Logo
During Conducted Immunity (CI) testing over an Audio Frequency range, voltages are applied to the supply lines of the Equipment Under Test (EUT) in order to confirm that the levels do not degrade its performance or cause deviations from the specifications of the EUT. An integrated Conducted Immunity system is included along with a function generator, amplifier, voltmeter, power meter and probe, injection transformer, load, capacitor (if required) as well as interconnecting cables with terminations suited to the devices provided. EMC Hire engineers will select equipment based on the customer's needs, so please provide as much information as possible (e.g. applicable standard, test level, etc.). The injection device will be an injection transformer which will subject the EUT to the applicable levels. The voltmeter can be used, depending on the standard applied, to measure the voltage at the EUT. A laptop containing RadiMation test software is included in the system, which will be preloaded with the appropriate test configurations including factors. A software operating procedure is also included to guide you through using the software as well as setup photos to help you assemble the equipment. We invite you to visit our facility for a demonstration and training, or EMC Hire can provide an engineer to set up the system at your location if necessary, or provide remote assistance via Teamviewer or Teams.